Counter Rollover Brings Down Rail Service

In October 2018 Hong Kong had "six hours of turmoil" in their rail service due to as signalling outage. The culprit has now been identified as counter roll-over.

South China Morning Post
https://www.scmp.com/news/hong-kong/transport/article/2178723/unknown-signalling-system-incompatibility-caused-october

Summary version: a system synchronization counter had been counting away since 1996 and required a system reset when it saturated.  (At least it didn't just roll over without anything noticing.)  But over the years two different systems with slightly different counter roll-over procedures were installed.  When rollover time came, they disagreed with each other on count value, paralyzing the system during the window until the second system shut down due to counter saturation.  Details below quoted from the official report. (https://www.mtr.com.hk/archive/corporate/en/press_release/PR-18-108-E.pdf)

The Detailed version:
"5.1.3. Data transmission between sector computers is always synchronized through an internal software counter in each sector computer. If any individual sector computer is individually rebooted, its counter will be re-initialized and will immediately synchronize to the higher counter figure for the whole synchronized network. Therefore, when the Siemens sector computers were commissioned and put into service in 2001/2002, the relevant counters were synchronized to those of the Alstom sector computers which were installed in 1996. If the counter reaches its ceiling figure, the associated sector computer will halt and need to be re-initialized. However the counter re-initialization arrangements for the two suppliers’ sector computers are different. The Alstom sector computers will be re-initialized automatically once their counters reach an inbuilt re-initialization triggering point approximately 5 hours before reaching the ceiling figure. However, this internal software function was not made known to the operators and maintainers. The Siemens sector computers do not have an automatic reinitialization function and therefore need to be manually reinitialized through rebooting in SER by maintenance staff.  
5.1.4 At around 05:26 hours on the incident day, the Alstom software counters reached the triggering point for automatic re- initialization while the Siemens sector computers continued counting up, creating an inconsistent re-initialization situation between the two interconnected sector computers at KWT (Alstom) and LAT (Siemens). This resulted in repeated execution of re-initialization followed by re-synchronization with the higher counter figure from LAT, in the KWT sector computer in an endless loop causing corresponding instability in all 25 Alstom sector computers in the system.  
5.1.5 When all the Siemens software counters reached the ceiling figure at around 10:22 hours, some 5 hours after the Alstom sector computers had passed their automatic re-initialization triggering point, the 8 Siemens sector computers halted as designed. Moreover, trains on the TKL had already encountered trainborne signalling failure earlier at 10:02 hours due to the around 20 minutes counter look ahead validity requirements. 
5.1.6 After the interconnections between the signalling systems of the relevant lines and the Alstom and Siemens sector computers between KWT and LAT were isolated, all sector computers were effectively rebooted to complete the entire re-initialization process and the signalling system for the four incident lines resumed normal. "
With credit for calling my attention to the report to:
Date: Sun, 30 Dec 2018 15:39:37 +0800
From: Richard Stein 
Subject: Re: MTR East Rail disruption caused by failure of both primary 
 and backup (Stein, RISKS-30.89)

Better Reboot Your Boeing 787 Every Three Weeks

Crashing after a prolonged up time due to a counter rollover or other problem is a classic mistake in computer software.  And, it just bit the Boeing 787. Again.

The Problem:

The Boeing 787 aircraft has three Flight Control Modules (FCMs) that are the subject of a new FAA Airworthiness Directive.  Based on that sentence alone, you want to make sure whatever that involves gets fixed before you fly on a 787!

The FAA says there is "a report" that all three FCMs can fail at the same time 22 days after they have been rebooted.  If you don't reboot the FCMs the FAA says this "could result in flight control surfaces not moving in response to flight crew inputs for a short time and consequent temporary loss of controllability."  This is FAA-speak for the airplane could crash. The're telling airlines to reboot the plane every 21 days to avoid this. Hope nobody forgets to do that! (In fairness, I understand it is likely that most planes get rebooted more often than this anyway. But this is not something you want to leave to chance.)

At this point we can only guess at the cause, but the usual guess is that it is a timer overflow problem. Let's hypothesize a 32-bit signed integer is counting the passing of time in milliseconds.  So a value of 32700 in that counter is 32.700 seconds.

How long until it overflows 31 bits of counting into the 32nd bit, which is the sign bit?

0x7FFFFFFF = 2147483647 ==> 2147483.647 seconds
2147483.647 seconds * (1 min/60 sec) (1 hr/60 min)(1 day/24 hr) = 24.9 days

Hmm, a bit longer than the 22 days the FAA reports.  Some time spent playing with various multipliers didn't seem to give a likely candidate.  Possible factors if it is a timer rollover would include fixed point math (e.g., time keeping in 256ths of a second) or scaling from a 400 Hz aircraft AC frequency. Or there could be some divided-down crystal oscillator frequency on the FCM that is involved.

Or, it could be something completely different.  Maybe there is memory that records operating parameters periodically and the system crashes when that fills up that memory (for example, logs that get downloaded every maintenance interval, with an expectation that the maintenance interval is more like a few days than a few weeks).

For now the cause is a bit of a mystery to us.  I'll bet the FCM engineers have a pretty good idea at this point. No doubt they'll issue a fix as fast as they can get the FAA to review it.

But the big news is that for the second time, the FAA is telling is telling the airlines they have to do a maintenance reboot of their planes.  Last time it was every 248 days. This time it's every 21 days.

It's bad enough that they have to reboot the infotainment systems once in a while.  For flight controls, this is not good news. This is the kind of problem that should be caught in design reviews.  Always think about what happens if any counter, timer, or data structure overflows.

Other Examples:

This is not the first time a problem with long-running software has happened beyond the usual memory leaks in everyday applications.  Some examples are:

Timer rollover bugs:
  • B787 needs to be rebooted every 248 days due to a likely timer overflow bug [Blog][NY Times] [FAA]
  • Air Traffic control loses contact with 400 aircraft due to a 32-bit time rollover in 2004 [IEEE Spectrum]
  • IBM: Interface adapters hang after 497 days of uptime [IBM]
  • Windows 95: hang after 49.7 days without reboot, counting in milliseconds [Microsoft]  (I met the engineers who found that one. And congratulated them on the significant feat of actually getting Windows 95 to run that long without crashing for some other reason!)
There are also plenty of date roll-over bugs:
  • NASA Deep Impact Comet Mission terminated unexpectedly when at 2**32 seconds after Jan 1, 2000 (a time rollover bug). [IEEE Software]
  • Y2K: on 1 January 2000 (overflow of 2-digit year from 99 to 00)   [Wikipedia]
  • GPS: 1024 week rollover on 22 August 1999 [USCG]
  • Year 2038: Unix time will roll over on 19 January 2038 [Wikipedia]
There are also somewhat related capacity overflow issues such
And floating-point roundoff issues (thanks to Dan for reminding me of this one):

  • Patriot Missile mishap after operating for 100 hours without a maintenance reboot [GAO]

If you want to dig further, there is a "zoo" of related problems on Wikipedia:  "Time formatting and storage bugs"

A Nice Rant About Representing Computer System Time

Here's a nice rant about dealing with time, time zones, daylight savings time, leap seconds, and why keeping things straight is so difficult. This especially applies to embedded systems which might not have a network connection, let alone access to a networked time service.

 The overall video series looks pretty interesting too, although it's more about computers in general than embedded computers specifically.  (Scroll down past the video link to see a list of how time-keeping bugs have caused severe outages and even deaths.)

"Summary: Published on Dec 30, 2013 A web app that works out how many seconds ago something happened. How hard can coding that be? Tom Scott explains how time twists and turns like a twisty-turny thing. It's not to be trifled with! (Embedded from YouTube; <computerphile>)"




Bonus content: here is a rogue's gallery of time goofs that I happen to include in my classroom lectures.  If you know of other high profile outages or worse please submit as comments and I'll update the list as we go. (Note: this is only bugs caused by bad time-keeping, not all software outages):
  • Feb. 1991: Patriot missile failure due to floating point time roundoff; 28 deaths (link)
  • Dec 31, 1999: Y2K
  • Feb. 2007: F-22 raptor computer system crash due to crossing the international date line (link)
  • Feb. 2008: Microsoft Zunes basically bricked by leap year bug (link) 
  • Mar. 2011:  iPhones spring back instead of springing forward (link)
  • Mar. 2012: Windows Azure leap-year bug takes down G-cloud (link)
  • Jul. 1, 2012: Leap second bug wreaks havoc upon on-line services using NTP (link)
  • Sep. 2013: Deep Impact comet mission ends due to calendar date rollover fault (link)
  • May 2015: Boeing 787 timer rollover bug crashes engine software after 248 days (link)
  • Jul. 1, 2015: Another leap second problem, but not nearly as bad as 2012 (link)
  • Feb. 2016: iPhone prank bricks iPhones if date set back to zero Unix time (link)
  • Feb. 2016: Leap year bug leaves passengers without bags at Dusseldorf airport (link)
  • Jan. 19, 2038 03:15:07 GMT:  Unix time rolls over ("Y2K for Unix")
(There are relatively few listings before 2010.  Don't think for a minute that time suddenly got harder. What got worse was probably more things can be broken and result in headlines due to timekeeping faults.)

Update 11/8/2016:  This is an entertaining and enlightening post about the quirks of time:  Falsehoods programmers believe about time and it has a follow-up of additional falsehoods

Counter Rollover Bites Boeing 787

Counter rollover is a classic mistake in computer software.  And, it just bit the Boeing 787.

The Problem:

The Boeing 787 aircraft's electrical power control units shut down if powered without interruption for 248 days (a bit over 8 months). In the likely case that all the control units were turned on at about the same time, that means they all shut down at the same time -- potentially in the middle of a flight. Fortunately, the power is usually not left on for 8 continuous months, so apparently this has not actually happened in flight.  But the problem was seen in a long-duration simulation and could happen in a real aircraft. (There are backup power supplies, but do you really want to be relying on them over the middle of an ocean?  I thought not.) The fix is turning off the power and turning it back on every 120 days.

That's right -- the FAA is telling the airlines they have to do a maintenance reboot of their planes every 120 days.

(Sources: NY Times ; FAA)


Analysis:

Just for fun, let's do the math and figure out what's going on.
248 days * 24 hours/day * 60 minute/hour * 60 seconds/minute = 21,427,200
Hmmm ... what if those systems keep time as an 32-bit signed integer in hundredths of a second? The maximum positive value for such a counter would give:
0x7FFFFFFF = 2147483647 / (24*60*60) = 24855 / 100 = 248.55 days.
Bingo!

If they had used a 32-bit unsigned it would still overflow after twice as long = 497.1 days.


Other Examples:

This is not the first time a counter rollover has caused a problem.  Some examples are:

  • IBM: Interface adapters hang after 497 days of uptime [IBM]
  • Windows 95: hang after 49.7 days without reboot, counting in milliseconds [Microsoft]  
  • Hong Kong rail service outage [Blog]
There are also plenty of date roll-over bugs:
  • Y2K: on 1 January 2000 (overflow of 2-digit year from 99 to 00)   [Wikipedia]
  • GPS: 1024 week rollover on 22 August 1999 [USCG]
  • Year 2038: Unix time will roll over on 19 January 2038 [Wikipedia]

There are also somewhat related capacity overflow issues such as 512K day for IPv4 routers.

If you want to dig further, there is a "zoo" of related problems on Wikipedia:  "Time formatting and storage bugs"